Modern smart thermostats are typically powered from the 24VAC transformer that's used for the relay. This is commonly called a "C" wire, and is from the opposite side of the transformer to the "R" wire.

One of the better descriptions I've seen is here

Now there's a second way of powering these thermostats; that's to use
an external 24VAC supply such as this one, which can be wired like this

So now the original HVAC wiring is still the R/W pair, but the additional power needed for the smarts comes from the wall-wart.

I currently only have a 2 wire system, but I can see a third (truncated) wire, so I could easily(ish) add a C wire.

One thing I can't decide, though, is which of these two options is better.

Normally, during the summer, I turn the power off to the furnace. (It's a gas furnace with electronic ignition, so it's simple; just throw the big red switch; power up in winter is just as simple). But if I do that then the thermostat will lose power and I'll lose benefits (eg ability to record temperature).

Alternatively the wall-wart would require an unsightly wire running up the wall to the thermostat... which I might be able to hide.

I'm also trying to think what would happen if the thermostat was wired backwards. In a 2-wire system this doesn't matter, but what will the consequences be if I added a C wire, or a wall-wart?

I should be able to check the wires are right, though.
If you don't have an account you can create one now.
HTML doesn't work in the subject.
More info about formatting

January 2026

S M T W T F S
    123
45678910
11121314151617
181920212223 24
25262728293031

Style Credit

Expand Cut Tags

No cut tags
Page generated Feb. 2nd, 2026 07:39 pm
Powered by Dreamwidth Studios